Chapter 5 Configuring a Typical Application Installation and Operation Manual
5-10 Configuring Gmux-2000 MiTOP-E1/T1 Ver. 1.0
Pseudowire Gateway
Config>Connection>Connection configuration - (BUNDLE 1)
Connection state Enable
Source CBID 16
Dest CBID 15
| Payload format V2
v TDM frame in packet 8
Jitter buffer in Ms[0-200] 15
OAM connectivity Disable
Payload type Data
| Far end type E1
OOS L bit mode TX OOS and L bit
| Destination IP 10.10.10.2
v Network slot port 6/1
Next hop 0.0.0.0
IP TOS 0
Adaptive clock Disable
VLAN tagging Disable
Figure
5-15. Configuring the Gmux-2000 Bundle Parameters
Connecting the E1 Port to the Bundle
Now associate the bundle with the E1 port 1 of the E1-PW/28 installed in I/O
slot 1 by specifying the just-configured bundle index number.
³ To connect the E1 port to the bundle:
From the Assign Entire Port to Bundle menu (Config > TS Assignment > Assign
entire port to bundle), select the bundle number and choose Connect Entire
Port to Bundle.
Pseudowire Gateway
Config>TS Assignment>Assign entire port to bundle
1. Bundle number[1 - 2000] ... (1)
2. Connect entire port to bundle
3. Disconnect entire port from bundle
Figure
5-16. Connecting the Entire E1 Port to the Bundle