Appendix C I2C Interface Management Installation and Operation Manual
C-10 Parameters MiRICi-E3T3 Ver. 2.2
Index R/W Parameter Length Description Default
Digit 3, Tx Clock:
0 = Rx clock
1 = Internal clock
Digit 7, Interface Admin Status:
0 = Down
1 = Up
0x51A R+W 1 Digit 0, TRDI:
0 = Normal operation
1 = Sends RDI alarm.
XXXX XXX0:
Normal operation
0x531 R+W 1 Fault Propagation caused by:
Digit 0, LOS
Digit 1, RLOL
Digit 2, AIS
Digit 3, RDI
Digit 4, LOF
Digit 5, FEAC
0 = Disable
0x532 R+W 1 Tx_disable behavior:
00 = NA – no impact
01 = 3 State
02 = AIS
0 = No impact
0x534 R+W 1 Flow Control:
0 = Disable
1 = Enable
1 = Enable
0x535 R+W 2 Fault Propagation Time Out:
0 – 3600 seconds
0
0x536 R+W 1 VCAT overhead
0 = Disable
1 = Enable
0 = Disable
0x537 R+W 1 LOS Behavior caused by:
Digit 0, LOS
Digit 1, RLOL
Digit 2, AIS
Digit 3, RDI
0 = Disable
0x538 R+W 1 GFP Payload FCS
0 = Disable
1 = Enable
0 = Disable
0x539 R+W 1 GFP with scrambler
0 = Disable
1 = Enable
1 = Enable
0x540 R+W 1 Protocol
0 = HDLC
1 = GFP
2 = cHDLC
For E3
0 = HDLC
For T3