RADview-EMS ASMi-52 User’s Manual Chapter 4 Performance Monitoring
E1/T1 Port Level – Statistics Menu 4-15
Table 4-8. 15 min Current Data Parameters (Cont.)
Parameter Possible Values/Remarks
Errored Seconds
(ES)
The number of errored seconds
0…899
Unavailable
Seconds (UAS)
The number of seconds that are unavailable
0…899
Severely Errored
Seconds (SES)
The number of severely errored seconds
0…899
Bursty Errored
Seconds (BES)
The number of bursty errored seconds
0…899
Loss of Frame
(LOFC)
Description of frame loss
Controlled Slip
Seconds (CSS)
The number of controlled slip seconds
0…899
Degraded
Minutes (DM)
The number of degraded minutes
0…15
CRC Error Event Description of CRC error event
CRC Average
Error Event
Description of CRC average error event
[Close] Click <Close> to close the 15 min Current Data dialog box
[Poll] Click <Poll> to poll the Agent
Viewing 15-Minute Interval Port Data
The 15 min Interval Data command enables you to view port data for all
15-minute intervals over the last 24 hours.
This command is available for the E1 port when the line type is E1-CRC
(G732N-CRC), or for the T1 port when the line type is ESF.
To view port data for all 15-minute intervals over the last 24 hours:
At the E1/T1 port level, select Statistics > 15 min Interval Data...