RAD Data comm DXC-100PSX Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 6
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
1993–2005 RAD Data Communications Ltd. Specifications are subject to change without prior notice.
All other trademarks are the property of their respective holders.
DXC-100
M
ultiservice Access Nodes
371-100-11/05
371-100-11/05
www.rad.com
International Headquarters
24 Raoul Wallenberg Street
Tel Aviv 69719, Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
North America Headquarters
900 Corporate Drive
Mahwah, NJ 07430, USA
Tel: (201) 529-1100
Toll free: 1-800 444-7234
Fax: (201) 529-5777
Protection
System and power supply
modules: 1:1
STM-1 and OC-3 modules: 1:1
E1/T1, E3, and T3 modules: N:1
Management Options
ASCII terminal
SNMP agent
Telnet
RADview PC
Management Ports
RS-232
10/100BaseT Ethernet
Indicators
STATUS (per power supply)
READY, LAN, CRITL, MAJOR,
MINOR (per system manager)
Push-button
ACO (Alarm cut off) momentary
alarm reset (per system manager)
Physical
Height: 26.7 cm (10.5 in 6U)
Width: 43.2 cm (17 in)
Depth: 35.6 cm (14 in)
Weight: 11 kg (25 lb)(without
modules)
Power Supply
100 to 240 VAC, 47 to 63 Hz
–48 VDC nominal
Power Consumption (max)
Standalone: 200W
Stacked: 288W per chassis
Environment
Temperature: 0–50°C
(32–122°F)
Humidity: Up to 90%,
non-condensing
ORDERING
Basic chassis, power supply, system
modules, I/O modules, cables, and
rack-mount kits are all ordered
separately.
BASIC UNIT
DXC-100/MN
Basic unit includes 6U high NEBS-3
certified modular optional redundant
DACS rack, 19-inch flush rack-mount
kit, no system modules, no PS modules.
POWER SUPPLY MODULES
DXC-100M-PS/AC
6U 100 to 240 VAC power supply
module
DXC-100M-PS/48
6U –48 VDC power supply module
SYSTEM MODULES
DXC-100M-SMC.2/?
System manager controller
DXC-100M-XNM/M
Node manager for Nest 1 only
DXC-100M-XCC/?
Expansion cross-connect module for
Nest 1 only
DXC-100M-XLC/M
Expansion link controller module, for
Nests 2 to 8 only
? Specify module type (default is main
and interface module set):
M for main, front-mounted module
IO for interface, rear-mounted
module
I/O MODULES
See separate data sheets for details.
PROTECTION SWITCH REDUNDANT
UNIT
DXC-100PSX/MN
3U high N:1 redundancy system chassis
with front-mounted fan and filter, no
power supplies, no system modules
DXC-100PSX-NC
3U nest controller module for
DXC-100PSX, with DB-9 connector
(only one required per chassis)
DXC-100PSX-PS/48
3U –48V DC power supply module for
DXC-100PSX
NETWORK MANAGEMENT SYSTEMS
RV-PC-SW/TDM
RADview PC for TDM applications
RV-HP-SW/TDM
RADview HPOV for TDM applications
RV-LIC/DXC-100
RADview activation key for DXC-100
SUPPLIED ACCESSORIES
RM-DXC-100/19/CNTR
19-inch rack-mount kit, center
mounting
RM-DXC100PSX/19
19-inch rack mount kit for DXC-100PSX
(one flush kit supplied with the unit)
CBL-100PSX-DNC
DXC-100PSX nest controller module
cable, 50 cm (20 in), DB-9 (male) to
DB-9 (male) (one cable supplied with
the DXC-100PSX-NC module)
CBL-DXC-100/ALARM
DSMC.2 interface DB-9 to X.25 alarm
cable (one cable supplied with the
DSMC.2 module)
AC power cord (when AC power supply
is ordered)
DC adapter plug (when DC power
supply is ordered)
OPTIONAL ACCESSORIES
CBL-DXLC/3
DXLC to DXCC cable, 4 twisted pairs,
3m (10 ft) long
CBL-DXLC/6
DXLC to DXCC cable, 4 twisted pairs,
6m (20 ft) long
RM-DXC-100/23/#
23-inch rack mount kit
RM-DXC100PSX/23/#
23-inch rack mount kit for
DXC-100PSX
# Specify rack mount placement:
CNTR for center mounting
FLUSH for flush mounting
Toll Free: 888-785-7393
Int'l: 1-951-694-1173
www.pulsewan.com
Vista de pagina 5
1 2 3 4 5 6

Comentarios a estos manuales

Sin comentarios