Chapter 2 Installation MBE Family Installation and Operation Manual
2-6 Installation and Setup
0
3
4
57
6
1
2
BOT
Rate
768
256
128
96
64
48
32
16
POS
0
1
2
3
4
5
6
7
00
33
44
5577
66
11
22
BOT TOP
Rate
768
256
128
96
64
48
32
16
POS
0
1
2
3
4
5
6
7
IL-4W IL-4WD
Figure 2-2. 4W Date Rate Selection
BOT- corresponds to the lower link connector.
TOP - corresponds to the upper link connector.
Table 2-2. MBE Four-Wire Data Rate
Data Rate
(kbps)
Range
km/miles
Selector Position
768 1.0/0.6 0
256 3.0/1.8 1
128 4.5/2.7 2
96 5.5/3.3 3
64 6/3.7 4
48 7/4.3 5
32 6.5/4.0 6
16 6/3.7 7
Note